01/2007
8.6 DP slave: MCP 310
8-202
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) -- 01/2007 Edition
Notice
The PROFIBUS address set in the S7 project for DP slave: MCP 310 must
match the PROFIBUS address set on the module (DIP switch S3).
There is no automatic adjustment!
The following data must agree:
1. SIMATIC configuration DP slave: MCP 310
PROFIBUS address
2. Machine control panel MCP 310
PROFIBUS address (DIP switch S3)
The active functions and hence the number of user data elements to be trans-
ferred are chosen by selecting the appropriate pre--configured module. The
modules are listed in the hardware catalog under DP slave: MCP 310. The fol-
lowing modules are available:
S Universal module (not applicable)
S standard
S standard, handwheel
S standard, extended
S standard, handwheel, extended
Module: standard
The module transfers the data for the ”Standard” function:
S Input data: 8 byte
Standard data
(8 bytes)
S Output data: 8 byte
Standard data
(8 bytes)
Module: standard, handwheel
The module transfers the data for the ”Standard” and ”Handwheel” functions:
S Input data: 12 bytes
Standard data
(8 bytes)
Absolute value
1st handwheel
(2 bytes)
Low byte
High byte
Absolute value
2nd handwheel
(2 bytes)
S Output data: 8 byte
Standard data
(8 bytes)
Adding a module
PROFIB
SDPCommun
c
on