EasyManua.ls Logo

Siemens Sinumerik 840DiE sl - Page 207

Siemens Sinumerik 840DiE sl
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01/2007
8.6 DP slave: MCP 310
8-207
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Arrangement of key signals in the input image of DP slave: MCP 310:
Table 8-2 Input image
Signals from machine control panel (keys)
Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
EB n+0 Spindle override Mode
*NC stop
S19
SP –
S36
SP 100%
S37
SP +
S38
Single
block
S16
JOG
S09
MDA
S10
AUTO
S13
EB n+1 Spindle Key Pos. 3
X50 3
Machine function
NC Start
S20
SP right
S39
*SP Stop
S40
SP left
S41
X50.3
REF
S02
REP
S01
TEACH
S11
EB n+2 Feedrate Mach. fu. Key Pos. 0
X50 4
Machine function
Feed Start
S35
*Feed Stop
S34
INC VAR
S03
X50.4
INC1000
S07
INC100
S06
INC10
S05
INC1
S04
EB n+3 RESET Key Pos. 2
X50 1
Key Pos. 1
X50 6
Feed override
S17
X50.1 X50.6
*F.over.16
X30.6
*F.over.8
X30.7
*F.over.4
X30.8
*F.over.2
X30.9
*F.over.1
X30.10
EB n+4 Arrow keys Optional customer keys
+
S50
S48
Rapid tra-
verse
S49
KT4
X52.2
KT3
X52.1
KT2
X51.3
KT1
X51.2
KT0
X51.1
EB n+5 Free K. Opt. K. Axis selection
T16
S18
KT5
X52.3
6
S47
5
S46
4
S45
Z
S44
Y
S43
X
S42
EB n+6 Freely assignable customer keys WCS/MCS Freely assignable customer keys
T9
S29
T10
S30
T11
S31
T12
S32
S33
T13
S12
T14
S14
T15
S15
EB n+7 Freely assignable customer keys
T1
S21
T2
S22
T3
S23
T4
S24
T5
S25
T6
S26
T7
S27
T8
S28
Signals marked with * are inverse signals.
The following information is to be found in the table for each input bit:
1st line: Default designation
2nd line: Key number (Sxy) or feedrate override switch (X30/X31), key-
switch (X50), optional customer keys (X52)
Input image
8 PROFIBUS DP Communication

Table of Contents