01/2007
11.7 Digital and analog I/O devices
11-389
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
11.7 Digital and analog I/O devices
The following digital and analog signal modules are available:
Digital I/O modules
MCI board extension module (option)
On the MCI board extension module (option) there are 4 digital inputs/
outputs (Section 2.3, Page 2-53).
PP 72/48
The I/O module PP 72/48 has 72 digital inputs and 48 digital outputs
(Section 2.11, Page 2-79).
ADI4
The ADI4 has two digital input and output bytes that are used for
ADI4–internal functions and as I/O signals at the interfaces of the mod-
ule (Section 2.12, Page 2-91).
SIMATIC S7: ET200 modules
Via the PROFIBUS DP it is possible to connect all subtypes of SIMAT-
IC–S7 I/O modules of type ET200 (e.g. ET200M) as long as they support
a data transmission rate of 12 Mbaud.
Analog I/O modules
SIMATIC S7: ET200 modules
See above.
Notice
The digital and analog input/outputs connected via the PROFIBUS DP are
equally available to both the NCK and PLC.
It is the sole responsibility of the user to avoid access conflicts:
S On the NCK side: Part program/synchronized action
S On the PLC side: PLC user program
/FB/ Description of Functions, Extended Functions,
A4 Digital and Analog NCK I/Os
11.7.1 Parameterization of the number of inputs/outputs used
The maximum number of digital or analog input/outputs that can be used for the
NCK is:
Total MCI board
extension
PROFIBUS
Modules
Analog inputs 8 8
Analog outputs 8 8
Digital inputs 36 4 32
Digital outputs 36 4 32