01/2007
11.8 Loadable compile cycles
11-400
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
11.8.1 Loading a compile cycle
To transfer the compile cycle to the control, the following requirements must be met:
S There is a network connection (TCP/IP) between the PCU and an external
computer (PC/PG) on which the compile cycle is located.
S Storage media can be connected to the PCU (e.g. USB FlashDrive) on
which the compile cycle is saved.
Perform the following operation to load one or more compile cycles into the NCK:
1. End the active SINUMERIK user interface (e.g., HMI Advanced) and acti-
vate the SINUMERIK desktop (see Section 5.4.1, Page 5-117).
2. Use Windows Explorer to copy the compile cycle file (e.g. ccresu.elf) from
the external computer (PC/PG) or the CD/disk drive to the following directory
on the PCU: F:\card\oem\sinumerik\oa\
3. Trigger a NCK reset to load the compile cycles into the NCK system soft-
ware.
11.8.2 Interface version compatibility
A SINUMERIK–specific interface is used for communication between the com-
pile cycle and NCK system software. Therefore, the interface version of a
loaded compile cycle must be compatible with the interface version of the NCK
system software. Each interface version is displayed under:
S Interface version of the NCK system software
HMI Advanced:
Diagnosis > Service displays > Version > NCU Version
Display (excerpt)
CC Interface Version:
@NCKOPI . . . .@Interfaces=<1st digit>.<2nd digit> . . . .
Loaded Compile Cycles:
. . . .
S Interface version of a compile cycle that has not yet been loaded
HMI Advanced (excerpt):
Services > <Medium> > Softkey: ”Properties”
Display:
Contents: Loadable compile cycle
Interface: . . . . @Interfaces=<1st digit>.<2nd digit> . . . .
S Interface version of a loaded compile cycle
HMI Advanced:
Diagnosis > Service displays > Version > NCU Version
Requirements
Execution
11 NCK Commissionin
with HMI Advanced