01/2007
11.8 Loadable compile cycles
11-401
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Display (excerpt)
CC Interface Version:
@NCKOPI . . . .
Loaded Compile Cycles:
<Identifier> <Version> <Date generated>
CC start address
_N_<Identifier><Version>IF<1st digit><2nd digit>_ELF . . .
Example:
_N_CLC407IF003001_ELF corresponds to interface version: 3.1
The following dependencies exist between the interface versionsof a compile
cycle and the NCK system software:
S 1st digit of the interface version number
The 1st digit of the interface version number of a compile cycle and the NCK
system software must be equal.
S 2nd digit of the interface version number
The 2nd digit of the interface version number of a compile cycle must be
less than or equal to the 2nd digit of the NCK system software.
Caution
If alarm 7200 is displayed after the NCK has booted, this means no compile
cycle has been loaded!
11.8.3 Software version of a compile cycle
The software version of a compile cycle is displayed under:
HMI Advanced:
Diagnosis > Service displays > Version > NCU Version
Display (excerpt)
CC Interface Version:
@NCKOPI . . . .
Loaded Compile Cycles:
<Identifier> <Version> <Date generated>
CC start address
_N_<Identifier><Version>IF<1st digit>.<2nd digit>_ELF . . .
Code=<Address> Data=<Address> . . .
Example:
_N_CLC407IF003001_ELF corresponds to SW version: 4.7
Note
The display of code and data range start addresses of a compile cycle are
provided for diagnostics purposes only and have no significance in normal
operation.
dependencies