01/2007
11.8 Loadable compile cycles
11-402
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
11.8.4 Supplementary conditions
The following checks are performed for all loaded compile cycles when the NCK
boots:
If the interface version of the compile cycle is incompatible with the interface
version of the NCK system software, the following alarm is displayed:
S Alarm ”7200 Version_conflict_with_CCNCKInterfaceVersion”.
If one compile cycle has a functional dependency on another, and this has not
been loaded in the NCK, the following alarm is issued:
S Alarm ”7200 CC<name>_ELF Loader_problem_from_dFixup”
If the compile cycle is not enabled in conjunction with SINUMERIK
840Di sl/840DiE sl, the following alarm is issued:
Not enabled for SINUMERIK 840Di sl
S Alarm ”7200 CC<name>_ELF NO_840Di”
Not enabled for SINUMERIK 840DiE sl:
S Alarm ”7200 CC<name>_ELF NO_EMBARGO”
Notice
If alarm ”7200 . . . ” is present after an NCK start–up, none of the loaded
compile cycles is active.
11.8.5 Activating and licensing technology functions
To activate the technological function loaded onto the NCK by means of the
compile cycle, the respective option must be set and licensed.
For information about how to activate and license options, please see Section
5.7, Page 5-127.
Each loaded compile cycle generates a technological function–specific global
machine data:
S $MN_CC_ACTIVE_IN_CHAN_<name>[n], where n = 0, 1
in the machine data number range 60900 to 60999.
You can activate the entire technological function in the individual channels or
individual subfunctions via the general NCK machine date mentioned above.
For a description of the machine data, please see Section 11.8.6, Page 11-403.
The individual technological functions are described in:
/FB3/ Description of Functions Special Functions
Sections TE1 to TE8
Interface
versions
dependencies
System enables
Activating and
licensing the
option
Activating the
technological
function
References
11 NCK Commissionin
with HMI Advanced