01/2007
11.11NCK/PLC diagnostics
11-406
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) -- 01/2007 Edition
11.11 NCK/PLC diagnostics
11.11.1 Menu: Diagnostics
The menu of the NCK/PLC diagnostics is in the following operating path:
S Operating area switchover > Diagnosis > NC/PLC Diagnosis > Diagnosis
NCK Reset NCK Default Data
6 running
MPF0
Program aborted
ROV
CHAN1
JOG Ref
Commiss--
ioning
RUN--P
RUN
STOP
PLC Default
Data
PLC Delete
Program
STOP
BUS 1
BUS 2
FORCE
BATF
BATL
SF
RUN
PLC
RUN
PLC
RUN--P
PLC
STOP
NCK
Default Data
NCK
Reset
PLC
Default Data
PLC
Delete Prg.
NCK latencies
Channel RESET
200
0
μs
Time (sec)
560
Diagnostics Settings
Acknowledge alarm 4065
>>
NCK PLC
Fig. 11-34 Menu: NCK/PLC diagnostics
The following functions are grouped together in the NCK group box:
S NCK state
The current state of the NCK is displayed via the output field:
-- 0 not started
-- 1 s t a r t e d
-- 2 initializing data
-- 3 initializing data
-- 4 s t a r t -- u p
-- 5 waiting for PLC
-- 6 running
-- F NCK error