15.4 Reading in a series startup file with HMI Advanced
15-465
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
To change the PLC operating status, proceed as follows:
S With 840Di start–up:
Start 840Di start–up Windows XP taskbar > Start > Programs >
SINUMERIK 840Di > 840Di Start–up.
Open the dialog box: Menu command Window > Diagnosis > NC/PLC.
S With HMI Advanced
Open the dialog box: Operating area switchover > Commissioning >
NC/PLC Diagnosis
S Change the PLC operating state: Group box PLC, buttons: STOP and ”RUN”.
S NCK and PLC must then be resynchronized: Group box PLC, buttons:
NC Reset”.
15.4 Reading in a series startup file with HMI Advanced
The process of reading in a series startup file is broken down into the following
steps:
1. Open the menu to read in a series startup file:
Operating area switchover > Services > key: ”>” > Standard commis-
sioning > Read in commissioning archive
2. Select the series startup file
3. Start read in: Start
Note
Because of the file extension ”.arc” of the series startup file, this is also called
archive.
Changing the PLC
operating status
15 User Data Backu