EasyManua.ls Logo

Siemens Sinumerik 840DiE sl - Interface Description

Siemens Sinumerik 840DiE sl
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01/2007
2.2 MCI2 board for 840Di sl
2-47
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Designation
Order No. (MLFB)
Bus connector RS–485 for PROFIBUS DP
and MPI
180° cable outlet
6GK1 500–0EA02
35° cable outlet, without PG connection socket
6ES7 972–0BA40–0XA0
35° cable outlet, with PG connection socket
6ES7 972–0BB40–0XA0
90° cable outlet, without PG connection socket
6ES7 972–0BA11–0XA0
90° cable outlet, with PG connection socket
6ES7 972–0BB11–0XA0
2.2.2 Interface description
Interfaces of the MCI board module
Table 2-1 Interface overview: MCI board
Interface
Designation Type
PROFIBUS DP X101 Socket
MPI/DP X102 Socket
MCI board extension X2 Plug connector
Buffer voltage X3 Plug connector
PCI bus X11 Direct connector
LED 1 DP1 LEDs
LED 2 DP2 LEDs
Interface description PROFIBUS DP interface (X101):
S Connection: 9–pin SUB–D socket connector
S Pin assignment
Table 2-2 Pin assignment: PROFIBUS DP interface (X101)
Pin
Designation Type
1)
Function
1 Not assigned
2 Not assigned
3 RS–DP B RS 485 differential signals
4 RTS O Request to Send
5 GNDext VO External ground
2)
6 P5ext VO Ext. 5V power supply
2)
7 Not assigned
8 XRS DP B RS 485 differential signals
9 Not assigned
1) VO Voltage Output
O Output
B Bidirectional
2) Pin 5 and 6 can only be used to supply the bus termination resistances
S Connecting cable: See Section 3.3.2, Page 3-103
Interface description MPI/DP interface (X102):
S Connection: 9–pin SUB–D socket connector
S Pin assignment
Order no.:
Bus connector
Interface overview
PROFIBUS DP
interface
(X101)
MPI/DP
interface
(X102)