Please note the following settings:
S Browser settings for using the A&D Mall:
Section 17.1.8, Page 17-482.
S Proxy settings for the download of license information:
Section 17.1.9, Page 17-483
17.3.3 Enabling/disabling SINUMERIK plug–ins
All plug–ins enabled for the Automation License Manager scan the communica-
tion interfaces when booting according to specific operations. If there is a large
number of enabled plug–ins, this can result in a significantly longer boot and
refresh time for the user interface.
To prevent this delay, you can disable the plug–in installed for handling the
SINUMERIK License Keys in dialog: ”Connect to target system”.
Perform the following actions to enable/disable the SINUMERIK plug–ins:
1. Start the Automation License Manager
2. Open the ”Connect to target system” dialog via menu command: Edit >
Connect to target system> PlugIn SINUMERIK
3. In the dialog, open tab: Settings
4. Enable/disable the plug–in by selecting/deselecting the appropriate checkbox.
5. Close the dialog box with OK
The Automation License Manager displays the data in the navigation and object
area according to the status of the SINUMERIK plug–in.
The folder symbols and names are displayed in the navigation area depending
on the status of the SINUMERIK plug–in and the communication link to the
SINUMERIK control:
S SINUMERIK plug–in disabled:
PlugIn SINUMERIK – – – – disabled – – – –
S SINUMERIK plug–in enabled, but no communication link with SINUMERIK
control:
SINUMERIK – online – – – – no link available – – – –
SINUMERIK – offline – – – – no data available – – – –
S SINUMERIK plug–in enabled, communication link established with
SINUMERIK control:
SINUMERIK <Control type> – <Hardware serial number>
Further settings
Background
Execution
Result
17 License Mana
ement