18.2 Expanded message frame configuration/evaluation of internal drive variables
18-511
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
S Configuring the additional drive actual values
The drive utilization for PDA11 is configured via the selection list of the cor-
responding parameter (PROFIDrive parameter P0916[x]) in Fig. 18-5.
File Edit Commissioning Operation Diagnostics Tools Help
SimoCom U 12A drive
Online to drive 12A => data are modified directly in the drive!
Configuratio
Analog input
Mechanics
Limitation
Digital input
Digital outpu
Analog outp
Monitoring
Controller
Traverse blo
Sh.–angl. en
PROFIBUS
Spindle pos
5 Torque reduction (TorRed)
6 Enc. 1 control word (G1_CTW)
7 No signal (NIL)
8 No signal (NIL)
9 No signal (NIL)
10 No signal (NIL)
11 No signal (NIL)
12 No signal (NIL)
13 No signal (NIL)
PROFIBUS OFF1 Control of clock–synchronized PROFIBUS
14 No signal (NIL)
15 No signal (NIL)
16 No signal (NIL)
5 Message word (MessW)
6 Enc. 1 status word (G1_STW)
7 Enc. 1 pos. act. val. 1 (G1_XACT1)
8 Enc. 1 pos. act. val. 1 (G1_XACT1)
9 Enc. 1 pos. act. value 2 (G1_XACT2)
10 Enc. 1 pos. act. val. 2 (G1_XACT2)
14 No signal (NIL)
15 No signal (NIL)
16 No signal (NIL)
Currently selected block (CurrBlo)
Digital inputs (DIG_IN)
Load
Analog input T. 56.x/14 (ADC1)
Analog input T. 24.x/20 (ADC2)
Speed actual value A (NACT_A)
1
1
12
1
3
Fig. 18-5
Configuring the additional drive actual values
Before configuring the extended message frames, you must first perform the
standard configuration on the NC for the drive.
How to proceed with the standard configuration of a drive is described in Sec-
tion 11.5.3, Page 11-314.
On the NC for the expanded message frame configuration, you only need to
activate PDA transfer in the respective system variable.
Option: ”Evaluation of internal drive variables”,
Order number (MLFB): 6FC5 251–0AB17–0BA0
NC machine data for activating the data transmission in the system
variables:
S MD 36730: DRIVE_SIGNAL_TRACKING[n] (acquisition of additional
drive actual values)
Note
After configuring the expanded message frames, the standard message frame
with which the axis is driven is only explicitly visible in the NC machine data:
S MD 13060: DRIVE_TELEGRAM_TYPE[n] (drive message frame type)
Step 3:
Configuring the
NC
Standard
configuration
Extended
message frame
configuration