Analog inputs
Table 12-30 Measured values in the voltage measurement operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Voltage value [V]
Overow - Deactivation
Overrange - up to 11.75V
0x19B5 6581
0.00152
10V
0x0CDA 3291 5 V
0x066D 1645 2.5V
0x0000 0 0V
0xF993 -1645 -2.5V
0xF326 -3291 -5V
0xE64B -6581 -10V
Underrange - Up to -11.75V
Underow - Deactivation
Table 12-31 Measured values in the current measurement operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Current value [mA]
Overow - Deactivation
Overrange - up to 23.5mA
0x1999 6553
0.00305
20mA
0x0CCC 3277 10mA
0x0000 0 0mA
0xF333 -3277 -10mA
0xE666 -6553 -20mA
Underrange - up to -23.5mA
Underow - Deactivation
Table 12-32 Measured values in the "temperature measurement" operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Temperature value [°C]
Overow
0x0A28 2590
0.1
259°C
0x03E8 1000 100°C
0x01F4 500 50°C
0x0000 0.0 0°C
0xFE0C -500 -50°C
0xFC18 -1000 -100°C
0xF830 -2000 -200°C
Underow
Connectable components
12.2PP 72/48D PN and PP 72/48D 2/2A PN
NCU 1750
136 Equipment Manual, 10/2023, A5E45627807B AH