EasyManua.ls Logo

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 - Page 136

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Analog inputs
Table 12-30 Measured values in the voltage measurement operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Voltage value [V]
Over󹪞ow - Deactivation
Overrange - up to 11.75V
0x19B5 6581
0.00152
10V
0x0CDA 3291 5 V
0x066D 1645 2.5V
0x0000 0 0V
0xF993 -1645 -2.5V
0xF326 -3291 -5V
0xE64B -6581 -10V
Underrange - Up to -11.75V
Under󹪞ow - Deactivation
Table 12-31 Measured values in the current measurement operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Current value [mA]
Over󹪞ow - Deactivation
Overrange - up to 23.5mA
0x1999 6553
0.00305
20mA
0x0CCC 3277 10mA
0x0000 0 0mA
0xF333 -3277 -10mA
0xE666 -6553 -20mA
Underrange - up to -23.5mA
Under󹪞ow - Deactivation
Table 12-32 Measured values in the "temperature measurement" operating mode
16-bit value (hex.) 16-bit value (dec.) Factor Temperature value [°C]
Over󹪞ow
0x0A28 2590
0.1
259°C
0x03E8 1000 100°C
0x01F4 500 50°C
0x0000 0.0 0°C
0xFE0C -500 -50°C
0xFC18 -1000 -100°C
0xF830 -2000 -200°C
Under󹪞ow
Connectable components
12.2PP 72/48D PN and PP 72/48D 2/2A PN
NCU 1750
136 Equipment Manual, 10/2023, A5E45627807B AH

Table of Contents

Related product manuals