Detailed Description
2.12 Block descriptions
PLC Basic Program Solution Line (P3 sl)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-181
Fig. 2-31 Star/delta switchover
More information about motor speed adjustment can be found in:
References:
/FB/ Description of Functions, Basic Machine; Spindles (S1);
Section: Configurable Gear Adjustments
/FB/ Description of Functions, Basic Machine; Velocities, Setpoint/Actual Value Systems,
Closed-Loop Control (G2)
Error message
If the parameter "SpindleIFNo" is not in the permissible range, the PLC is stopped with
output of interrupt message number 401702.
Special features
When parameterizing "TimeVal" with the value 0, a default value of 100 ms is used. With a
value of less than 50 ms, the minimum setting of 50 ms is applied.
The block must be called unconditionally.
Note
Switchover does not take place if the spindle is in an axis mode such as M70, SPOS.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals