Note
The Ethernet interfaces have what is called autocrossing functionality, i.e. when required,
transmit and receive lines are switched over.
Position of the Ethernet interfaces
X120 P1 (PN/IE-OP)
X130 P1 (PN/IE-NET)
X127 P1 (PN/IE)
Figure 7-4 Ethernet ports
Cable specification
Table 7-10 Cable specification for X120, X130, and X127
Characteristic Version
Connector type RJ45 socket
Cable type Industrial Ethernet cable (as of CAT5)
Max. data transmission rate: 10/100/1000 Mbit/s
Max. cable length 100 m
Connecting
7.7 Use of Ethernet interfaces
NCU 1760
66 Equipment Manual, 02/2020, A5E45627861B AB