A5E01040182-01; 43-TV-25-40 Iss.1 GLO Oct 06 UK 1
1. Connections
1) Earth/ground
2) 24VDC Inst. power (option)
3) AC supply 100-250VAC
4) CJC Connector (option)
5) 24V TXP Supply (option)
6) RS485 port (option)
7) USB host (option)
8) Ethernet connection (std)
D200 rear panel
Analogue Input board - 6 ch expansion (option). D200 = Slot B
1 2 3 4 5 6 7 8 9
CJC
- +
*
13 14 15 16 17 1810 11 12
- +
*
- +
*
- +
*
- +
*
- +
*
Relay Alarm - 4 or 8 channel (option). D200 = Slot G
1 2 3 4 5 6 7 8 9
NO C NO C NO C NO C NO C NO C NO C NO C
10 11 12 13 14 15 16
Digital Input/Output - 8 channel (option). D200 = Slot G
Key: NO = Normally Open, C = Common, NC = Normally Closed,
Ohms 3 wire R/T 4 wire R/T 2 wire R/T
mV, V T/C Passive T/C Active Current
(Slot B only)
Slot B
Slot G
Slot A
ETHERNET
USB
RS485
24Vdc TX
5
6
7
4 (CH9 - 14)
3
2
1
8
24V TX Power Supply 2-way conn (5), RS485 Modbus port (6)
and USB port (7) are all on the Comms option card
Analogue Input - 3 or 6 channel. D200 = Slot A
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18
- +
*
- +
*
- +
*
- +
*
- +
*
- +
*
Card 3 CH. 6 CH. 9 CH. 12 CH.
A 1-3 1-6 1-3 1-6
B 9-14 9-14
CH1 CH2 CH3 CH4 CH5 CH6
CH9 CH10 CH11 CH12 CH13 CH14
1 2 3 4 5 6 7 8 9
NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input across NO, C
(CH1-3/CH1-6)
2. Setup Menu
Inputs
All Analogue Inputs default to 12V
Select Input channel
• Setup input Type. V, A, Ohms, RT, TC
• Select Sample Rate
• Select Range / RT / TC Type
Use Back button to return to Setup Menu
Pens
By default Pen 1 displays
Analogue Input 1, Pen 2
displays Analogue 2 etc.
Localization
Set Date
and Time
Select the Menu button
from the Process Screen
Configure
Setup
Edit
Field IO
Analogue In
Pens
General
Finish Commit
Localisation
Back
Settings (Main Menu > Configure)
Settings
Set Time
Settings for Language and Time Zones, etc.
General
Credits
Factory
Options
Select Options in Credits menu, tick firmware
options to enable. Go to Finish and Commit
Select Pen
• Setup Scale
• Set Alarms, if required
Setup Logging (required to Log and
Save data in memory)
Use Back button to return to Setup Menu
Quick Start Guide - SIREC D200 Display Recorder
s

Other manuals for Siemens SIREC D200

Question and Answer IconNeed help?

Do you have a question about the Siemens SIREC D200 and is the answer not in the manual?

Siemens SIREC D200 Specifications

General IconGeneral
BrandSiemens
ModelSIREC D200
CategoryData Loggers
LanguageEnglish