Error Cause Remedy
No main power
The mains switch or the power
supply is not plugged in correctly.
There is no power.
Check the cables and the cable connections
and replace defective components, if necessa‐
ry.
Temperature sensor overload The temperature of the motor is too
high.
Check the motor and the application that is
driven by the motor.
After triggering, the motor can only be
switched on again if the temperature has
reached the release position of the temper‐
ature sensor. The acknowledgment de‐
pends on the "Response to overload tem‐
perature sensor" parameter that has been
set.
Temperature sensor wire break A wire has broken in the sensor cable
of the temperature sensor.
Check the sensor line and the temperature sen‐
sor.
Temperature sensor short-circuit A short-circuit has occurred in the
sensor line of the temperature sensor.
Thermal motor model overload
The motor feeder is overloaded.
The motor temperature has ex‐
ceeded a limit.
Check the motor and the applications driv‐
en by the motor.
You can switch on the motor again after the
cooling-down period has expired or after
deleting the thermal motor model. The ac‐
knowledgment depends on the set "Re‐
sponse to overload thermal motor model".
Motor overload protection - shuto󹪜
Safety-related shuto󹪜
1)
The module has detected a problem
on the channel and has therefore exe‐
cuted a safety-related shuto󹪜. The
possible reason is a discrepancy error.
Check the channel and eliminate the cause.
Asymmetry limit error exceeded A limit for asymmetry has been ex‐
ceeded. Asymmetry can cause an
overload. Possible causes:
Phase failure
Fault in the motor windings
Check the motor feeder and the motor.
Asymmetry shuto󹪜 Additional tripping in the case of
asymmetry
Current limit error exceeded The current has exceeded a limit. Check the application driven by the motor.
Current limit error undershot The current has undershot a limit.
Current limit error shuto󹪜 Additional tripping in the event of a
current limit error overshoot or un‐
dershoot.
Ground fault limit error exceeded The ground-fault monitoring has re‐
sponded. An impermissibly high re‐
sidual current is 󹪞owing.
Check the connecting cable of the motor for
damage.
Electronics supply voltage too low The supply voltage is below the per‐
mitted value.
Check the power supply (load rating, voltage
range).
Bus error Fault in the 󹪝eldbus communication.
You will 󹪝nd further information in
the manual for the 3RW5 communi‐
cation module in question.
Check the bus connection.
Check the bus parameters.
Messages and diagnostics
9.4 Errors and remedial actions of the 3RW55 and 3RW55 Failsafe soft starters
SIRIUS 3RW55 and 3RW55 Failsafe Soft Starters
Equipment Manual, 02/2022, A5E35630887002A/RS-AF/006 253

Table of Contents

Other manuals for Siemens SIRIUS 3RW55

Related product manuals