Servo control
4.17 Travel to fixed stop
Drive functions
174 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
4.17
Travel to fixed stop
This function can be used to move a motor to a fixed stop at a specified torque without a
fault being signaled. When the stop is reached, the specified torque is established and is
then continuously available.
The desired torque derating is brought about by scaling the upper/motor-mode torque limit
and the lower/regenerative-mode torque limit.
Application examples
Screwing parts together with a defined torque.
Moving to a mechanical reference point.
Signals
For PROFIdrive telegrams 2 to 6, the following signals are automatically interconnected:
Control word 2, bit 8 (STW2.8)
Status word 2, bit 8 (ZSW2.8)
For PROFIdrive telegrams 102 to 106, the following signals are also interconnected:
Message word, bit 1 (MELDW1)
Process data M_red to the scaling of the torque limit
When the "basic positioner" function module is activated, the signals listed above are
automatically interconnected to the basic positioner.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals