Servo control
4.18 Vertical axes
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
179
With a vertical axis without mechanical weight compensation, electronic weight
compensation can be set by offsetting the torque limits (p1532). The torque limits specified in
p1520 and p1521 are shifted by this offset value.
The offset value can be read in r0031 and transferred in p1532.
To reduce compensation once the brake has been released, the torque offset can be
interconnected as a supplementary torque setpoint (p1511 or p1513). In this way, the
holding torque is set as soon as the brake has been released.
Function diagrams (see SINAMICS S120/S150 List Manual)
5060
- Torque setpoint, switchover control mode
5620
- Motoring/generating torque limit
5630
- Upper/lower torque limit
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0031
p1511[0...n]
CI: Supplementary torque 1
p1512[0...n]
CI: Supplementary torque 1 scaling
p1513[0...n]
CI: Supplementary torque 2
p1520[0...n]
/motoring
p1521[0...n]
CO: Torque limit, lower/regenerative
p1532[0...n]