Vector control
5.14 Pole position identification
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
261
5.14.3
Notes regarding pole position identification
A suitable technique for the motor is selected using parameter p1980. The following
techniques are available:
Voltage pulsing 1st harmonic (p1980 = 1)
Voltage pulsing 2-stage (p1980 = 4)
Voltage pulsing 2-stage inverse (p1980 = 6)
Voltage pulsing 2nd harmonic inverse (p1980 = 8)
Impressing DC current
All of these techniques are only possible at standstill. The fast pole position identification can
be selected if a faster switch-on is required (p1780.13 = 1).
Supplementary conditions
The following supplementary conditions apply for the pulsed techniques (p1980 = 1, 4, 6, 8):
This procedure can be used for both braked and non-braked motors.
The specified current magnitudes (p0325, p0329) must be sufficient to provide a
significant measuring result (p0325 is only used for p1980 = 4).
Technique p1980 = 4 is recommended if the air gap manifests significant asymmetry (e.g.
magnets are embedded in the rotor). Technique p1980 = 1 should be applied if the air
gap is constant.
Technique p1980 = 8 is recommended for synchronous reluctance motors.
Technique p1980 = 6 is used for synchronous motors with a high reluctance torque
component.
The following constraints apply when impressing DC current (p1980 = 10):
The motor must be free to move and it may not be subject to external forces (no
hanging/suspended axes).
If a motor holding brake is being used, then this must be opened.
The technique is recommended if there is no magnetic asymmetry (e.g. symmetrical air
gap).
5.14.4
Messages and parameters
Faults and alarms (see SINAMICS S120/S150 List Manual)
F07413
Drive: Commutation angle incorrect (pole position identification)
A07967
Drive: Automatic encoder adjustment/pole position identification incorrect
F07968
Drive: Lq
-Ld measurement incorrect
F07969
Drive: Pole position identification incorrect
F07970
Drive: Automatic encoder adjustment incorrect

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals