Basic information about the drive system
13.4 BICO technology: Interconnecting signals
Drive functions
954 Function Manual, 11/2017, 6SL3097-4AB00-0BP5
13.4.5
Notes on BICO technology
BICO interconnections to other drives
The following parameters are available for BICO interconnections to other drives:
r9490 Number of BICO interconnections to other drives
r9491[0...9] BI/CI of BICO interconnections to other drives
r9492[0...9] BO/CO of BICO interconnections to other drives
p9493[0...9] Reset BICO interconnections to other drives
Copying drives
When a drive is copied, the interconnection is copied with it.
Binector-connector converters and connector-binector converters
Binector-connector converter
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
p2080[0...15] BI: PROFIdrive PZD send bit-serial
Connector-binector converter
A 32-bit integer double word or a 16-bit integer word is converted to individual digital
signals.
p2099[0...1] CI: PROFIdrive PZD selection receive bit-by-bit
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n] CO: Fixed value_%_1
p2901[0...n] CO: Fixed value_%_2
p2930[0...n] CO: Fixed value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals