6. Tighten the ange bolts as follows:
– Observe the torques:
MAWP 160 bar (2320 psi) 40Nm
MAWP 420 bar (6092 psi) 75Nm
7. To fulll the requirement according to DGRL 2014/68/ EU, perform a pressure test for devices
with MAWP 420 bar (6092 psi).
Result
The device is ready for operation.
After you have replaced the process anges, the measuring accuracy of the device may be
outside the specication.
Pressure test
Test pressure 240bar (PN 160bar • 1.5) 630bar (PN 420bar • 1.5)
Rise time 60seconds 60seconds
Hold time 60seconds 60seconds
Pressure drop 30seconds 30seconds
Ensure that the measured pressure remains stable until the end of the hold time.
Replacing spare parts
5.3Replacing the process anges
SITRANS P320/P420
Service Manual, 11/2023, A5E44914141-AC 33