EasyManua.ls Logo

Siemens SITRANS F FM100 - IO-Link Diagnosis Information

Siemens SITRANS F FM100
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS FM100
A5E48762204-AA page 55
17.2 IO-Link diagnosis information
Event
Code
[hex]
Event
Code
[dec]
Name
Device
Status
Type
Definition
0x7710
30480
Short Circuit
Error
check installation
0x8C10
35856
Process Variable Range Overrun
Warning
process data
uncertain
0x8C20
35872
Measurement Range Overrun
Error
check application
0x8C30
35888
Process Variable Range
Underrun
Warning
process data
uncertain
0x1838
6200
1. Test Event For Protocol
Testing
Error
first test event
0x1839
6201
2. Test Event For Protocol
Testing
Error
secont test event
0x183A
6202
Flow MRE Overrun
Warning
flow measuring
range overrun
0x183B
6203
Flow MRS Underrun
Warning
flow measuring
range underrun
0x183C
6204
Flow Overflow Overrun
2
Warning
flow overflow
range overrun
0x183D
6205
Flow Underflow Underrun
2
Warning
flow underflow
range underrun
0x183E
6206
Flow Cutoff Out
Warning
out of flow cutoff
range
0x183F
6207
Temperature MRE Overrun
Warning
temperature
measuring range
overrun
0x1840
6208
Temperature MRS Underrun
Warning
temperature
measuring range
underrun
0x1841
6209
Temperature Overflow Overrun
2
Warning
temperature
overflow range
overrun
0x1842
6210
Temperature Underflow
Underrun
2
Warning
temperature
underflow range
underrun
0x1843
6211
NVM Error
4
Error
non-volatile
memory is corrupt
0x1844
6212
Subslave Lost
Error
communication to
subslave
interrupted
0x1845
6213
Subslave Not Found
4
Error
cummunication to
subslave couldn`t
be astablished
0x1846
6214
Emptypipe
Warning
no media in tube
0x1847
6215
Temperature Sensor Error
4
Error
no sensor attached
0x1848
6216
Measuring Circuit Saturated
2
Warning
ADC out of range
0x1849
6217
Counter Overflow
2
Error
volume or
partvolume counter
overflowed
0x184A
6218
Dosing Timeout
Warning
indicades that the

Related product manuals