EasyManua.ls Logo

Siemens SITRANS F FM100 - IO Link ISDU Parameter Table

Siemens SITRANS F FM100
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS FM100
A5E48762204-AA page 57
17.4 IO Link ISDU parameter table
Index
[hex]
Name
Description
Factory default
Max Value
Min Value
Length
[Bytes]
Data Type
Access
System
0x0002
SystemCommand
See Table
"Comand Codes"
1
UIntegerT
W
Product Identification (Vendor specific parameters)
0x0010
VendorName
Siemens AG
max. 20
StringT
R
0x0011
VendorText
www.siemens.com
/processinstrumen
tation
max. 32
StringT
R
0x0012
ProductName
SITRANS FM100
max. 16
StringT
R
0x0013
ProductID
[exact model code]
max. 16
StringT
R
0x0014
ProductText
Electromagnetic
flowmeter
max. 32
StringT
R
0x0015
Serialnumber
only read
parameter
max. 8
StringT
R
0x0016
HardwareRevision
max. 8
StringT
R
0x0017
FirmwareRevision
Firmware Revision
is constant in FW
max. 8
StringT
R
0x0018
ApplicationDevice
Tag
tag name is from
user configurable
32
StringT
R/W
0x0019
FunctionTag
function tag is
from user
configurable
32
StringT
R/W
0x0020
LocationTag
location tag is
from user
configurable
32
StringT
R/W

Related product manuals