Pressure equipment directive (PED/DGRL) 93/23/EG
ATEX Directive 94/9/EG
PED directive
Pressure Equipment Directive" (PED) is mandatory for all pressure equipment sold within the
EU and EFTA.
Siemens Flow Instruments products comply with PED as stated in the following table.
Table 2-1 MAG 1100 and MAG 1100 HT PED compliance
Flange
mm
MAG 1100 MAG 1100 HT MAG 1100 F
Ceramic PFA Ceramic Ceramic PFA
2 EXC.PED N/A N/A N/A N/A
3 EXC.PED N/A N/A N/A N/A
6 EXC.PED N/A N/A N/A N/A
10 EXC.PED EXC.PED N/A EXC.PED EXC.PED
15 EXC.PED EXC.PED EXC.PED EXC.PED EXC.PED
25 EXC.PED EXC.PED EXC.PED EXC.PED EXC.PED
40 PED EXC.PED PED PED EXC.PED
50 PED PED PED PED PED
65 PED PED PED PED PED
80 PED PED PED PED PED
100 PED PED PED PED PED
Siemens Flow Instruments products confirms to PED by following the tables below.
EXC. PED = Excluded from PED under SEP or LVD
PED= Product covered by PED
N/A= Size/pressure outside of PED scope or not available in the size range
CAUTION
All products sold outside of EU and EFTA are excluded from the Pressure Equipment
directive, also products sold into certain market sectors are excluded. These include
1. Meters used in networks for the supply, distribution and discharge of water.
2. Meters used in pipelines for the conveyance of any fluid from offshore to onshore.
3. Meters used in the extraction of petroleum or gas, including christmas tree and manifold
equipment.
4. Any meter mounted on a ship or mobile offshore platform.