4.6.3 Mounting with a threaded type adapter
To mount a MAG 1100 F with threaded type adapters, follow these steps:
1. Prepare the pipeline with a suitable fitting.
2. Assemble the sensor and adapters together with the gaskets.
3. Tighten the threaded connectors by using a C-spanner.
4.7 Torques values
Note
Torque values are calculated on the basis of use of gaskets.
DN
mm/inch
Nm
2 /
1
/
12
13
3 /
1
/
8
13
6 /
1
/
4
13
10 /
3
/
8
13
15 /
1
/
2
16
25 / 1 30
40 / 1
1
/
2
54
50 / 2 90
65 / 2
1
/
2
90
80 / 3 90
100 / 4 115