Technical data
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
49
Version MAG 3100 P MAG 3100 MAG 3100 HT
With compact transmitter
MAG 5000/6000 -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F)
MAG 6000 I -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F)
MAG 6000 I Ex de -10 … +60 ºC (14 … 140 °F) -10 … +60 ºC (14 … 140 °F) -10 … +60 ºC (14 … 140 °F)
1
Conditions also dependent on liner characteristiques
Table 8- 3 Operating pressure [abs.bar]
1
Version MAG 3100 P MAG 3100 MAG 3100 HT
PTFE Teflon
DN 15 ... 300 (½" … 12")
:
0.3 ... 40 bar (4 ... 580
psi)
- DN ≤ 300 (≤ 12"):
0.3 ... 50 bar (4 ... 725
psi)
- 350 ≤ DN ≤ 600 (14" ≤
DN ≤ 24"):
0.3 ... 40 bar (4 ... 580
psi)
DN 15 ... 300 (½" … 12")
(130/180 °C (266
°F/356ºF)):
0.3/0.6 ... 50 bar (4/8 ...
725 psi)
180 ºC (356 ºF)
PTFE has factory mounted
grounding SS rings type E &
SS terminal box
PFA
- DN 15 ... 150 (
½
" … 6"):
Vacuum 0.02 ... 50 bar (0.29
... 725 psi)
- DN 15 ... 150 (
½
" … 6"):
Vacuum 0.02 ... 50 bar (0.29
... 725 psi)
- DN 15 ... 150 (
½
" … 6"):
Vacuum 0.02 ... 50 bar (0.29
... 725 psi)
Neoprene
0.01 ... 100 bar
(0.15 ... 1450 psi)
EPDM
0.01 ... 40 bar (0.15 ... 580
psi)
Linatex®
0.01 ... 40 bar
(0.15 ... 580 psi)
Ebonite
0.01 ... 100 bar
(0.15 ... 1450 psi)
1
Maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges
Table 8- 4 Mechanical load/Vibration
Version MAG 3100 P MAG 3100 MAG 3100 HT
Description 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
Sensor 3.17 grms
Sensor with compact MAG
5000/6000 mounted
transmitter
3.17 grms
MAG 6000 I/6000 I Ex
mounted transmitter:
1.14 grms