Technical data
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
51
Version MAG 3100 P MAG 3100 MAG 3100 HT
Grounding Electrode
material
PTFE: None
PFA: Hastelloy
Material as measuring
electrodes
Exceptions - see ordering
data
No grounding electrodes
Terminal box (remote
version only)
Standard fibre glass
reinforced polyamide
Stainless steel AISI 316
(1.4436)
Standard fibre glass
reinforced polyamide
Stainless steel AISI 316
(1.4436)
Stainless steel AISI 316
(1.4436)
Cable entries
Remote installation
2 x M20
2 x ½" NPT
2 x M20
2 x ½" NPT
2 x M20
2 x ½" NPT
Compact installation MAG 5000/MAG 6000:
4 x M20 or 4 x ½" NPT
MAG 6000 I:
2 x M25 (for
supply/output)
2 x ½" NPT
MAG 6000 I Ex de:
2 x M25 (for
supply/output)
2 x ½" NPT
MAG 5000/MAG 6000:
4 x M20
4 x ½" NPT
MAG 6000 I:
2 x M25 (for
supply/output)
2 x ½" NPT
MAG 6000 I Ex de:
2 x M25 (for
supply/output)
2 x ½" NPT
-
Table 8- 7 Certificates and approvals
Version MAG 3100 P MAG 3100 MAG 3100 HT
Calibration
Standard production
calibration, calibration
report shipped with
sensor
Zero-point, 2 x 25 % and 2 x
90 %
Zero-point, 2 x 25 % and 2 x
90 %
Zero-point, 2 x 25 % and 2 x
90 %
Conforms to PED (All EN1092-1 flanges
conforms to PED) – 97/23
EC1) CRN
PED (All EN1092-1 flanges
conforms to PED) – 97/23
EC1) CRN
PED (All EN1092-1 flanges
conforms to PED) – 97/23
EC1) CRN
Material certificate EN
10204 3.1
On request On request On request