Technical data
8.4 Process fluid conductivity
SITRANS F M MAG 5100 W
42 Operating Instructions, 11/2010, A5E03063678-02
Temperature (°C) Flange
specifications
Flange rating
-5 10 50 90
Sizes DN 15 ... 300 (order no. 7ME6520 only)
PN 10 10.0 10.0 10.0 8.2
PN 16 10.0 16.0 16.0 13.2
EN 1092-1
PN 40 40.0 40.0 38.7 37.7
ANSI B16.5 150 lb 10.0 19.7 19.7 16.2
Table 8- 9 Imperial measures (pressure in psi)
Temperature (°F)
Flange
specifications
Flange rating
23 50 120 200
Sizes 1" ... 78"
PN 10 145 145 141 136
PN 16 232 232 225 219
EN 1092-1
PN 40 580 580 561 547
ANSI B16.5 150 lb 286 286 280 261
AWWA C-207 Class D 150 150 150 150l
Sizes ½"... 12" (order no. 7ME6520 only)
PN 10 145 145 145 119 EN 1092-1
PN 16 145 232 232 191
ANSI B16.5 150 lb 145 286 286 235
8.4 Process fluid conductivity
Compact installation
Liquids with an electrical conductivity ≥ 5 μS/cm.
Remote installation
Standard cable
Cabel length
Conductivity
of medium
[µS/cm]
[m]
300
200
1005
300
200
100
5
150
600 900
[ft]
300