1)
Lithium batteries are subject to special transportation regulations accord-ing to United Nations
"Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required
to observe these regu-lations. This may influence both transport time and costs.
Communication IrDA: Standard integrated infrared communication interface with
MODBUS RTU protocol
Add-on modules:
RS 232 serial interface with MODBUS RTU (Rx/Tx/GND),
point to point with max. 15 m cable
RS 485 serial interface with MODBUS RTU (+/-/GND),
multidrop with up to 32 devices with max. 1000 m cable
MODBUS RTU protocol is an open protocol (further information
available on request)
Serial speed 1200, 2400, 4800, 9600, 19200, 38400 Baud
Battery power supply
1)
Auto detection of power source with displayed symbol for remaining
power. In battery mode, excitation frequency is manually selected
Internal battery pack: 2 D-Cell 3.6 V / 33 Ah
External battery pack: 4 D-Cell 3.6 V / 66 Ah
12-24 V AC/DC power supply Input voltage range: 12-24 V AC/DC (10-32 V AC/DC)
Power consumption during line: 2 VA
Isolation: Class II
Fuse: 1000 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
115/230 V AC mains power Input voltage range: 115/230 V AC, +15% to 20%, 50-60 Hz
supply Power consumption during mains: 2 VA
Isolation: Class II
Fuse: 250 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
Input cable for Factory mounted PUR cable with 2 x 1 mm
2
12-24 V AC/DC and (brown, blue), length = 3 m
115/230 V AC power supply Resistant to sunlight and water
Outer diameter 7 mm
Rated voltage (V AC) 300/500 V AC
Testing voltage (V AC) 2000 V AC
Temperature range (°C): Fixed laying 40 to +90 °C
Flexible application 30 to +80 °C
Minumum bending radius 28 mm, (fixed installation)
Maximum pulling force 200 N