MAG 8000 & MAG 8000 CT
6
SFIDK.PS.026.D9.02
2. Installation
The sensor must always be completely full with
liquid.
Therefore avoid:
Air in the pipe
Installation at the highest point in the pipe
system
Installation in vertical pipes with free outlet.
For partially filled pipes or pipes with downward
flow and free outlet, the flowmeter should be
located in a U-tube.
Installation instructions
The water meter can be installed between two
reducers (e.g. DIN 28545). With an 8° reducer,
the following pressure drop curve applies. The
curves are applicable to water.
Example:
A flow velocity of 3 m/s (10 ft./sec.) (V) in a
sensor with a diameter reduction from DN 100
to DN 80 (4" to 3") (d
1
/d
2
= 0.8) gives a pressure
drop of 2.9 mbar (0.04 psi).
Installation in large pipes
(MAG 8000)