EasyManua.ls Logo

Siemens SITRANS F M MAGFLO - Remote Installation - at the Sensor; Remote Installation - Transmitter

Siemens SITRANS F M MAGFLO
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS F M MAGFLO
®®
®®
®
6
SFIDK.PS.026.E5.02
ENGLISH
2.3.1 Remote installation -
At the sensor
Fit and connect the electrode and coil cables
as shown in “Electrical connections”.
The unscreened cable ends must be kept as
short as possible.
The electrode cable and the coil cable must be
kept separate to prevent interference.
Tighten the cable glands well to obtain opti-
mum sealing.
Remove the SENSORPROM
®
unit from the
sensor and mount it in the terminal block in the
transmitter.
2.3.2 Remote installation -
Transmitter
No power up with open lid -
Do not open lid while power
on
Fit the SENSORPROM
®
memory unit in the transmitter.
The SENSORPROM
®
unit is supplied with the sensor in the terminal box.
2. Installation

Related product manuals