Flow Net totalizer in
meter display
(Bi-directional)
Pulse output forward Uni-directional
mode
Volume [m
3
]
Pulse output net forward Bi-direction‐
al mode
Volume [m
3
]
Volume [m
3
] Internal calcula‐
tion
Delivered volume Internal calcula‐
tion
Delivered volume
18 - 20 −12+20= 8
Total accounted volume
[m
3
]
Forward/Reverse
18F 30F 18F
Encoder output interface read out
MSD LSD
Digits in MAG 8000 display 1 2 3 4 5 6 7 8
Model Size Unit Display configuration Q
3
Digits after
dec. point
7ME 6820 2Y DN50 (2") m
3
0 0 0 0 0 0 0 0 63 1
7ME 6820 3F DN65 (2½") m
3
0 0 0 0 0 0 0 0 100 1
7ME 6820 3M DN80 (3") m
3
0 0 0 0 0 0 0 0 160 1
7ME 6820 3T DN100 (4") m
3
0 0 0 0 0 0 0 0 250 1
7ME 6820 4B DN125 (5") m
3
0 0 0 0 0 0 0 0 400 1
7ME 6820 4H DN150 (6") m
3
0 0 0 0 0 0 0 0 630 1
7ME 6820 4P DN200 (8") m
3
0 0 0 0 0 0 0 0 1000 1
7ME 6820 4V DN250 (10") m
3
0 0 0 0 0 0 0 0 1600 1
7ME 6820 5D DN300 (12") m
3
0 0 0 0 0 0 0 0 1600 1
Parameter 305 Decimal Point should be configured to "1 digit after decimal point" in case
Encoder interface module is selected in MAG 8000, MAG 8000 CT and MAG 8000 Irrigation;
otherwise proper reading from the device cannot be performed.
10.7 Meter uncertainty
To ensure continuous accurate measurement, water meters must be calibrated. The calibration
is conducted at Siemens flow facilities with traceable instruments referring directly to the
physical unit of measurement according to the International System of Units (SI).
Therefore, the calibration certificate ensures recognition of the test results worldwide, including
the US (NIST traceability).
Technical data
10.7 Meter uncertainty
SITRANS MAG 8000
Operating Instructions, 11/2018, A5E03071515-AE 101