Param‐
eter ID
Meter
version
Display
view
Parameter/data type Factory settings Data range
Fixed parameter or meter data that are not changeable
120 All - Actual flow meter status 0 to 255, binary presented with
information 1 for bit 0
1: Totalizer 1 or 2 changed or
reset
2: Tariff setting changed or re‐
set,
3: Tariff register changed or re‐
set
4: Date - time changed
5: Alarm have been active
6: Fault log has been reset
7: Hardware key has been acti‐
vated
8: Meter has been powered up
If none of the above is active, no
flag is set
130 All - Menu active 63=all menus active 0 to 63, binary presented with
information
1 for bit 0
1: Operator menu
2: Meter info menu
3: Service menu
4: Log menu
5: Statistic menu
6: Revenue menu
If none of the above is active, the
message is: None active
131 All - Default operator menu index Totalizer 1 Totalizer 1, Totalizer 2, Actual
Flow rate, Fault codes, Custom‐
er Totalizer
Appendix
C.2 Parameter lists
SITRANS MAG 8000
138 Operating Instructions, 11/2018, A5E03071515-AE