Table A-13 Output, MASS 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02201 2200 2 Byte Current Output 1 selection:
• 0 = O
• 1 = Massow
• 2 = Fraction A
• 3 = Fraction B R/W
• 4 = Volumeow
• 5 = Sensor temp.
• 6 = Density
• 7 = % fraction A
R/W
4:02202 2201 2 Byte Current Output 1 direction:
• 1 = Unidirectional
• 2 = Bidirectional
R/W
4:02203 2202 2 Byte Current Output 1 range:
• 0 = 0 - 20 mA
• 1 = 4 - 20 mA
• 2 = 4 - 20 mA + Alarm
R/W
4:02204 2203 4 Float Current Output 1 time constants R/W
4:02206 2205 2 Byte Digital Output 1 function:
• 0 = O
• 1 = Pulse
• 2 = Frequency
• 3 = Error Level
• 4 = Error Number
• 5 = Direction/Limit
• 6 = Batch
R/W
4:02207 2206 2 Byte Pulse 1 selection:
• 0 = Uninitialized
• 1 = Massow
• 2 = Fraction A
• 3 = Fraction B
• 4 = Volumeow
R/W
4:02208 2207 2 Byte Pulse 1 direction:
• 1 = Unidirectional
• 2 = Bidirectional
R/W
Modbus holding registers
A.6 Output
Modbus RTU RS 485
46 Operating Instructions, 03/2021, A5E00753974-AB