Table A-23 Display settings, MASS 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02901 2900 2 Byte Language:
• 0 = English
• 1 = Deutsch
• 2 = Français
• 3 = Dansk
• 4 = Svenska
• 5 = Suomeksi
• 6 = Russian
• 7 = Español
• 8 = Italiano
• 9 = Português
R/W
4:02902 2901 2 Byte Display line 1:
• 0 = Massow
• 1 = Volumeow
• 2 = Fraction A
• 3 = Fraction B
• 4 = % Fraction A
• 5 = Totalizer 1
• 6 = Totalizer 2
• 7 = Sensor temperature
• 8 = Density
R/W
4:02903 2902 2 Byte Display line 2:
• 0 = Text for line 3
• 1 = Totalizer 2
• 2 = Massow
• 3 = Massow %
• 4 = Volumeow
• 5 = Volumeow %
• 6 = Fraction A text
• 7 = Fraction A
• 8 = Fraction A %
• 9 = Fraction B text
• 10 = Fraction B
• 11 = Fraction B %
• 12 = % Fraction A
• 13 = Density
• 14 = Sensor temperature
• 15 = Totalizer 1
R/W
Modbus holding registers
A.11 Display settings
Modbus RTU RS 485
Operating Instructions, 03/2021, A5E00753974-AB 55