EasyManua.ls Logo

Siemens SITRANS F US - Page 167

Siemens SITRANS F US
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
165
Raw Flow Units
30537
8
String
String_In
8
UINT16
n/a
BD(Byte)
17
8
Total
30143
4
Real
Analog_In
12
Float
129
33-21h S
ADF(Float)
7
1
Total Units
30557
8
String
String_In
12
UINT16
131
33-21h
BD(Byte)
25
8
Sonic Vel Path 1
30157
4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
Sonic Vel Path 2
30159
4
Real
Analog_In
14
Float
n/a
ADF(Float)
9
1
Sonic Vel
30155
4
Real
Analog_In
15
Float
n/a
ADF(Float)
10
1
Sonic Vel Units
30577
8
String
String_In
16
UINT16
n/a
BD(Byte)
33
8
Signal Strength
Path 1
30167 2 Integer Analog_In 16 Float n/a ADF(Float) 11 1
Signal Strength
Path 2
30168 2 Integer Analog_In 17 Float n/a ADF(Float) 12 1
Signal Strength 30165 2 Integer Analog_In 18 Float n/a ADF(Float) 13 1
Sig Strength
Units
30593 8 String String_In 20 UINT16 n/a BD(Byte) 41 8
Aeration
30171
2
Integer
Analog_In
19
Float
n/a
ADF(Float)
14
1
Aeration Units
30609
8
String
String_In
24
UINT16
n/a
BD(Byte)
49
8
Liquid Name
30745
8
String
String_In
28
UINT16
n/a
BD(Byte)
57
8
Liquident
30229
4
Real
Analog_In
20
Float
n/a
ADF(Float)
15
1
Liquident Units
30677
8
String
String_In
32
UINT16
n/a
BD(Byte)
65
8
Specific Gravity
30237
4
Real
Analog_In
21
Float
129
14-0Eh
ADF(Float)
16
1
S.G. Units
30689
8
String
String_In
36
UINT16
131
14-0Eh
BD(Byte)
73
8
API
30247
4
Real
Analog_In
22
Float
129
17-11h
ADF(Float)
17
1
API Units
30705
8
String
String_In
40
UINT16
131
17-11h
BD(Byte)
81
8
Kg/m3
30253
4
Real
Analog_In
23
Float
129
20-14h
ADF(Float)
18
1
Kg/m3 Units
30713
8
String
String_In
44
UINT16
131
20-14h
BD(Byte)
89
8
Base S.G.
30259
4
Real
Analog_In
24
Float
129
23-17h
ADF(Float)
19
1
Base S.G. Units
30721
8
String
String_In
48
UINT16
131
23-17h
BD(Byte)
97
8
Base API
30265
4
Real
Analog_In
25
Float
129
26-1Ah
ADF(Float)
20
1
Base API Units
30729
8
String
String_In
52
UINT16
131
26-1Ah
BD(Byte)
105
8
Base Kg/m3
30271
4
Real
Analog_In
26
Float
129
29-1Dh
ADF(Float)
21
1
Base Kg/m3
Units
30737 8 String String_In 56 UINT16 131 29-1Dh BD(Byte) 113 8
Status: Spacing
Path 1
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
Status: Empth
Path 1
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1
Status: Rate
Path 1
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1
Status: Fault
Path 1
10024 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 5 1
Status: Aeration
Path 1
10025 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 6 1
Status: Memory
Path 1
10026 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 7 1
Status: Makeup
Path 1
10027 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 8 1
Status: Interface
Path 1
10028 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 9 1