Loading...
Setup
3.4 Inputs and outputs
FST030
110 Function Manual, 04/2017, A5E35693328-AA
3.4.3.2
Active operation (read only)
Description
Shows application possibilities.
Setting Active operation not possible, use passive wiring; Active operation possible, hardware is
able to drive the current loop
Default
-
Related
Path
Setup → Inputs and outputs → Channel 1 - output with HART → Active operation
3.4.3.3
PV selection
Description
Primary value - Sets a process value as primary variable. Loop current represents the
primary variable.
Setting
Volume flow; Mass flow; Standard volume flow (only hydrocarbon and gas applications);
Flow velocity; Sound velocity; LiquIdent (only hydrocarbon applications); Density; Kinemat-
ic viscosity; Pressure; Medium temperature; Standard density (only hydrocarbon and gas
applications); Standard kinematic viscosity (only hydrocarbon applications); API gravity
(only hydrocarbon applications); Standard API gravity (only hydrocarbon applications);
Specific gravity (only hydrocarbon applications); Standard specific gravity (only hydrocar-
bon and gas applications); Auxiliary temperature; Sensor temperature; Standardizing factor
(only hydrocarbon and gas applications)
Default
Volume flow
Related
Path
Setup → Inputs and outputs → Channel 1 - output with HART → PV selection
3.4.3.4
Direction
Description
Flow direction filter applicable for process values mass flow/volume flow/flow
velocity/standard volume flow rate (only hydrocarbon and gas applications).
Setting
Positive; Negative; Bidirectional; Bidirectional (symmetric)
Default
Positive
Related
Path
Setup → Inputs and outputs → Channel 1 - output with HART → Direction