Setup
3.4 Inputs and outputs
FST030
Function Manual, 04/2017, A5E35693328-AA
127
Setting
256 Standard density above alarm limit; 257 Standard density above warning limit; 258
Standard density below warning limit; 259 Standard density below alarm limit; 260 API
gravity above alarm limit; 261 API gravity above warning limit; 262 API gravity below warn-
ing limit; 263 API gravity below alarm limit; 264 Standard API gravity above alarm limit; 265
Standard API gravity above warning limit; 266 Standard API gravity below warning limit;
267 Standard API gravity below alarm limit; 268 Specific gravity above alarm limit; 269
Specific gravity above warning limit; 270 Specific gravity below warning limit; 271 Specific
gravity below alarm limit; 272 Std. spec. grav. above alarm limit; 273 Std. spec. grav.
above warning limit; 274 Std. spec. grav. below warning limit; 275 Std. spec. grav. below
alarm limit
Default
None
Related
Path
Setup → Inputs and outputs → Channel 2 - output → Status output → Process alarms (4)
3.4.4.7.8 Totalizer alarms
Description
Selection of alarm items that impact the output. Applicable if Status mode = Alarm item.
Setting
136 Totalizer 1 above alarm limit; 137 Totalizer 1 above warning limit; 138 Totalizer 1 -
below warning limit; 139 Totalizer 1 below alarm limit; 140 Totalizer 2 - above alarm limit;
141 Totalizer 2 above warning limit; 142 Totalizer 2 below warning limit; 143 Totalizer 2
below alarm limit; 144 Totalizer 3 above alarm limit; 145 Totalizer 3 above warning limit;
146 Totalizer 3 below warning limit; 147 Totalizer 3 below alarm limit
Default
None
Related
Path
Setup → Inputs and outputs → Channel 2 - output → Status output → Totalizer alarms
3.4.4.7.9 Channel 1 - alarms
Description
Channel 1 - alarms
Setting
153 CH1 loop cur. in lower saturation; 154 CH1 loop cur. in upper saturation; 155 CH1 loop
current deviation; 158 CH1 cable break
Default None
Related
Path Setup → Inputs and outputs → Channel 2 - output → Status output → Channel 1 - alarms