Maintenance and diagnostics
4.4 Diagnostics
FST030
268 Function Manual, 04/2017, A5E35693328-AA
Overflow; Underflow; Fail-safe behaviour active
Operation mode is set to Frequency output
The pulse output has reached maximum pulse output frequency; Fail-safe behaviour active
Operation mode is set to Pulse output
This parameter is only available if
is set to Current output, Frequency output
or Pulse output.
Path
Maintenance and diagnostics → Diagnostics → Inputs and outputs → Channel 2 - output →
4.4.3.2.5 Pulse counter (read only)
Description
This parameter shows the number of pulses since startup/last reset.
This parameter is only available if
is set to Pulse output.
Path
Maintenance and diagnostics → Diagnostics → Inputs and outputs → Channel 2 - output →
4.4.3.2.6 Reset pulse counter
Description
The pulse counter can be reset.
This parameter is only available if
is set to Pulse output.
Path
Maintenance and diagnostics → Diagnostics → Inputs and outputs → Channel 2 - output →