2-5
1010ENFM-3B
Section 2
To scroll the option list to [On] press then . [Enter Code?] appears at the top of
the Display Screen.
To select the first character, use the numeric keys or . To move the cursor to the first
character position press .
To move the cursor to the second character position .
Repeat the selection process for the second character. Continue this process until all the required
characters (8 max.) appear in the field.
To store code press . [Confirm Code ?] appears at top of the Display screen. Retype code
exactly as described above.
Pressing moves the cursor to the Site Security option list.
To scroll the option list to [Site Security: On] press . Once you turn on Site Security,
you must enter the correct code to turn it off.
To activate Site Security press
2.1.5 HOW TO DELETE A SITE SETUP
If you attempt to save a Site Setup when memory is full, the screen will show [Memory Full]. If you get this
message after issuing a Save/Rename Site command, you’ll have to delete an unneeded Site Setup to
clear memory space. The Datalogger and Site Storage share a common memory pool, so a large amount
of logged data could also trigger the [Memory Full] message. For how to clear Datalogger memory, see
[Meter Facilities/Datalogger Control]. The Defragment Command may also secure more memory (see
Meter Facility/Memory Control Menu).
To Delete a stored Site Setup:
To highlight [Delete Site] press .
To access the [Delete Site] option list press .
Move the cursor to the site name of the site setup you want to delete.
To delete the obsolete site setup press .
2.1.6 HOW TO SAVE/RENAME A SITE SETUP
The Save/Rename Site command copies data from Active Memory to the Site Storage Memory. Saved
Site Setups can be recalled for future use. This menu cell allows you to save a Site Setup at any time
during the programming process. However, you must recall and complete the Site Setup in order to
achieve operation.
When you access the Save/Rename Site menu cell, the name of the most recently created Site Setup
(see Create/Name Site) appears automatically. If this name is acceptable, you can press <ENT> to save
the Site Setup. You can change the listed site name by following the procedure below. You may select up
to eight characters. If you decide to use numbers or a decimal point in the site name, you can type these
characters directly from the keypad.