4.4 Inlet and outlet conditions
Inlet and outlet conditions
To achieve accurate ow measurement it is essential to have straight lengths of inlet and outlet
pipes and a certain distance to pumps and valves.
It is also important to centre the owmeter in relation to pipe anges and gaskets.
Figure4-5 Inlet and outlet conditions
Installation in partially lled pipes
For partially lled pipes or pipes with downward ow and free outlet the owmeter should be
located in a U-tube.
Installation in large pipes
The owmeter can be installed between two reducers (for example DIN 28545). At α ≤ 8° the
following pressure drop curves apply. The curves are applicable to water.
Installing/Mounting
4.4Inlet and outlet conditions