[µS/cm]
50
40
20
5
30
10
50
300 400 500
[m]
100
200
[ft]
15001200900
150 300
600
Conductivity
of medium
Special cable
Cable length
8.5 Liner selection
Liner Applications
EPDM Drinking water applications (not hydrocarbons)
NBR General purpose, sea waters
8.6 Electrode selection
Electrodes
Hastelloy C The preferred choice for water and wastewater, chemicals, food
and beverage, and pharmaceutical industries
Technical speci󹪝cations
8.6Electrode selection
SITRANS FMS500
Operating Instructions, 01/2024, A5E52677520-AA 51