Description Speci󹪝cation
Relative humidity 95 %
Mechanical environment resistance class 4M3 for industrial enclo‐
sure
IEC 60068-2-64 test Fh: Ran‐
dom vibration
IEC 60068-2-27 test Ea and
guidance: Impact
Climatic resistance class 4K4H
IEC 60068-2-2 test B: Dry heat
IEC 60068-2-1 test A: Cold
IEC 60068-2-78 test Cab: Damp
heat, steady state
IEC 60068-2-14 test N: Change
of temperature
EMC performance
Emission
Immunity
EN 55011 / CISPR-11
EN/IEC 61326-1 (Industry)
NAMUR
Table 7-28 Process medium conditions
Description Speci󹪝cation
Process medium tempeature within the acceptable temperature
range for the sensors
(-40to230°C for High Tempera‐
ture 991 sensors)
Fluid must be sonically conductive -
Operation outside the Reynolds transition region for best accuracy -
Table 7-29 Performance section
Description Speci󹪝cation
Approvals
ATEX Zone 2
IECEx Zone 2
FM Class I Div. 2
FMc Class I Div. 2
Accuracy ± 0.5 ... 1 % for velocities above 0.3
m/s and >10 diameters straight run
Repeatability ± 0.25 % (based on ISO 11631)
Pipe size range 12.7 ... 10 m (0.5 ... 394")
Wall Thickness Range 0.64 ... 76.2 mm (0.025 ... 3.0")
Pipe material Any sonically conductive material
(steel, plastic, aluminum, glass, ce‐
ment, ductile iron, copper)
Technical speci󹪝cations
7.9Operating conditions
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF 107