EasyManua.ls Logo

Siemens SITRANS FS130 - Wiring Tool

Siemens SITRANS FS130
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Power supply L/+ N/-
Active/+ Active/ -
Passive/+ Passive/-
Active/+ Active/ -
Passive/+ Passive/-
Active/+ Active/ - Active/+ Active/ -
Passive/+ Passive/- Passive/+ Passive/-
NO NO NO NO
NC NC NC NC
Channel 1 HART
Current output HART
Channel 2 output
Current, Frequency, Pulse and Status
Channel 1 MODBUS
Channel 1 PROFIBUS
Ch2
HW configuration
SW configuration
Power supply
Ch1
Terminals
Ch4
Ch3
In
+ (B) - (A)
Out
+ (B) - (A)
In
+ (B) - (A)
Out
+ (B) - (A)
Channel 3 & 4 Relay
Status output
Channel 3 & 4 Input and output
Outputs: Current, Frequency, Pulse and Status
Inputs: Digital
Figure4-7 Terminals/con󹪝guration overview
Ex and non-Ex versions
For Ex versions active or passive current output is preselected at ordering and cannot be
changed.
Non-Ex versions can be connected as either active or passive.
4.6.1.2 Wiring tool
Use the wiring tool for connecting the cables in the compact enclosure transmitter.
The wiring tool is located in the application terminal compartment.
Figure4-8 Wiring tool location
1. Insert wiring tool hook into receptor slot.
2. Press wiring tool wedge into top slot to spread clamp plates.
Connecting
4.6Connecting industrial enclosure
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF 57

Table of Contents

Related product manuals