1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Power supply L/+ N/-
Active/+ Active/ -
Passive/+ Passive/-
Active/+ Active/ -
Passive/+ Passive/-
Active/+ Active/ - Active/+ Active/ -
Passive/+ Passive/- Passive/+ Passive/-
NO NO NO NO
NC NC NC NC
Current, Frequency, Pulse and Status
Channel 3 & 4 Input and output
Outputs: Current, Frequency, Pulse and Status
Inputs: Digital
Figure4-7 Terminals/conguration overview
Ex and non-Ex versions
• For Ex versions active or passive current output is preselected at ordering and cannot be
changed.
• Non-Ex versions can be connected as either active or passive.
4.6.1.2 Wiring tool
Use the wiring tool for connecting the cables in the compact enclosure transmitter.
The wiring tool is located in the application terminal compartment.
Figure4-8 Wiring tool location
1. Insert wiring tool hook into receptor slot.
2. Press wiring tool wedge into top slot to spread clamp plates.
Connecting
4.6Connecting industrial enclosure
SITRANS FS130 & FS230