5. Connect wires to terminals using wiring tool.
– Industrial enclosure:
Active current output Passive current output
⑤ C ⑥ Cp-
④ Ca+ ⑤ C
Functional Earth Functional Earth
Active current output Passive current output
6. Tighten cable gland.
Note
For Ex versions active or passive current output is preselected at ordering and cannot be
changed.
Non-Ex versions can be connected as either active or passive.
Note
Load
Signal output: < 500 Ω at 14 to 24 VDC (active), 14 to 30 VDC (passive)
Relay output: 30 VAC/VDC, 100 mA
Passive signal input: 15 to 30 VDC, 2 to 15 mA
Connecting
4.6Connecting industrial enclosure
SITRANS FS130 & FS230
62 Compact Operating Instructions, 12/2023, A5E38755607-AF