EasyManua.ls Logo

Siemens SITRANS FS130 - Local Display

Siemens SITRANS FS130
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING
Hazardous contact voltage
Risk of injury through hazardous contact voltage when the device is open or not completely
closed.
The degree of protection speci󹪝ed on the nameplate or in Technical speci󹪝cations (Page97)
is no longer guaranteed if the device is open or not properly closed.
Make sure that the device is securely closed.
WARNING
Risk of explosion when media above 100 °C 󹪞ows through the process 󹪞ange
Explosion protection is no longer guaranteed and the approval is nulli󹪝ed.
It is prohibited for media above 100 °C to continually 󹪞ow through the process 󹪞ange.
WARNING
Loss of explosion protection
Risk of explosion in hazardous areas if the device is open or not properly closed.
Close the device as described in Connecting (Page35).
WARNING
Hot surfaces
Risk of burns resulting from hot surfaces.
Take corresponding protective measures, for example by wearing protective gloves.
Note
Verify proper operation and con󹪝guration of all analog inputs
Incorrect con󹪝guration can have a negative impact on 󹪞ow compensation and produce errors in
󹪞ow rate.
5.2 Local display
The device is commissioned/operated with the buttons on the local display.
The buttons are actuated by touching the glass panel on the appropriate button. The
graphical display above the buttons gives a menu-guided operation of the individual device
Commissioning
5.2Local display
SITRANS FS130 & FS230
86 Compact Operating Instructions, 12/2023, A5E38755607-AF