WARNING
Improper connection after maintenance
Risk of explosion in areas subject to explosion hazard.
Connect the device correctly after maintenance.
Close the device after maintenance work.
Refer to Connecting (Page35).
The device is maintenance-free. However, a periodic inspection according to pertinent directives
and regulations must be carried out.
An inspection can include, for example, check of:
Ambient conditions
Seal integrity of the process connections, cable entries, and cover
Reliability of power supply, lightning protection, and grounds
6.3.1 On-board battery replacement
Note
The on-board battery is used to maintain real time clock and should only be replaced with
Panasonic BR1225A/BN.
Siemens spare part number: A5E41372210
The battery is located in the transmitter cassette. The transmitter cassette location can be
found in the exploded view.
6.4 Return procedure
Enclose the bill of lading, return document and decontamination certi󹪝cate in a clear plastic
pouch and attach it 󹪝rmly to the outside of the packaging.
Service and maintenance
6.4Return procedure
SITRANS FS130 & FS230