SITRANS FS230
A5E38755607-AA, 02/2017
21
6
Technical data
6.1
Power
Table 6-1 Power supply
Description
Specification
Supply voltage
100 to 240 V AC +10/-10%, 47 to 63 Hz
20 to 27 V DC +10/-10%
Power consumption
15 VA/7.5 W
Fluctuation
Transient overvoltages up to the levels of overvoltage
category II
Temporary overvoltages occurring on mains supply only
Reverse polarity protection (y / n)
Y
Galvanic isolation
3000 V AC
6.2
HART interface
Table 6-2 HART communication
Description
Specification
HART revision
7.5
Supported Device Managers
SIMATIC PDM V8.2 SP1 or newer
Supported Device Description (EDD)
V1.00.00
6.3
Operating conditions
Table 6-3 Basic conditions
Description
Specification
Ambient temperature
(Humidity max. 90 %)
Operation:
Transmitter without display
Display
-40 to +60 °C (-40 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
Ambient temperature
(Humidity max. 90 %)
Storage: -40 to +70 °C (-40 to +158 °F)
Climate class DIN 60721-3-4
Altitude
Up to 2000 m (6560 ft)
Relative humidity 95 %
Bump resistance
On request
Shock resistance
On request
Thermal shock
On request
Vibration resistance
On request
EMC performance
Emission
Immunity
EN 55011 / CISPR-11
EN/IEC 61326-1 (Industry)
NAMUR NE 21

Table of Contents