External DSL connec‐
tions
Sensor connections RTD connections
L
o
Group IIC
Groups IIB, III
Group IIA
134μH
675μH
1.35μH
67μH
348μH
697μH
1.87mH
7.47mH
14.9mH
L
o
/R
o
Group IIC
Groups IIB, III
Group IIA
17.8μH/Ω
71.2μH/Ω
142μH/Ω
18.0μH/Ω
72.2μH/Ω
144μH/Ω
NA
NA
NA
Table 7-12 I/O connections active - wallmount enclosure
HART active Modbus I/O 2 active I/O 3 active I/O 4 active
Terminals 4, 5 4, 5, 6, 7 8, 9 11, 12 14, 15
U
o
28VDC 4.2VDC 28VDC 28VDC 28VDC
I
o
85mA 118mA 87mA 87mA 87mA
P
o
584.5mW 124mW 601mW 601mW 601mW
C
o
Group IIC
Groups IIB, III
Group IIA
72nF
639nF
2139nF
4200nF
10000nF
10000nF
78nF
645nF
2145nF
78nF
645nF
2145nF
78nF
645nF
2145nF
L
o
Group IIC
Groups IIB, III
Group IIA
1.64mH
16.4mH
36.0mH
2.56mH
10.2mH
20.5mH
1.46mH
15.7mH
34.7mH
1.46mH
15.7mH
34.7mH
1.46mH
15.7mH
34.7mH
Table 7-13 Output parameters - industrial enclosure
External DSL connections
U
o
17.42V DC
I
o
459mA
P
o
2000mW
C
o
Group IIC
Groups IIB, III
338nF
1969nF
L
o
Group IIC
Groups IIB, III
134μH
675μH
L
o
/R
o
Group IIC
17.8μH/Ω
Technical speci󹪝cations
7.6Energy limitation parameters FST030
SITRANS FS130 & FS230