Sensor clamping screw Spacer bar pin and reference hole
Customer pipe Mounting strap
7ME39600*** Mounting Frame Larger pipes may need additional mounting
straps
Spring Clip (not present on some mounting
frame models)
Orientation for Single path sensor at the 9
o'clock position
Spacer bar Orientation for Dual path sensor at the 10
and 2 o'clock positions
Figure3-9 Re󹪞ect mount
Note
Additional mounting options
For additional mounting options see FSS200 installation manual
3.8 Incorrect mounting
NOTICE
Incorrect mounting
The device can be damaged, destroyed, or its functionality impaired through improper
mounting.
Before installing ensure there is no visible damage to the device.
Mount the device using suitable tools. See operating instructions.
Installing/mounting
3.8Incorrect mounting
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF 33